start of test
1  3  13  14  21  16 / 1729 483676
end of test
1 3 13 16 50 28
duration: 2.32 hours

files at start of test
689_0301o
699_0301o
C:\Documents and Settings\AntCal\My Documents\AsteRx\log_0000.sbf

files at end of test
689_0301q
699_0301q
C:\Documents and Settings\AntCal\My Documents\AsteRx\log_0002.sbf


** this test was conducted wtih 
1) Ashtech chokering on reference pier
2) ** change to tracking loop settings for 689 PTU rx

before (standard):
  /par/raw/gdplls={band=3.0,order=1,guid=100}
  /par/raw/plls={band=3.0,order=1,guid=100}

commands issued to change the settings:
set,/par/raw/gdplls/band,10.0
set,/par/raw/gdplls/order,3
set,/par/raw/gdplls/guid,0
... do the same for /par/raw/plls/*

new (modified to Geo++ settings):
print,/par/raw/gdplls/:on
  /par/raw/gdplls={band=10.0,order=3,guid=0}
print,/par/raw/plls/:on
  /par/raw/plls={band=10.0,order=3,guid=0}